<< Click to Display Table of Contents >> DA Case Summary Tension |
The Tension summary chart is an X-Y chart of the belt tension at one selected point on the conveyor, for selected operating case(s) during the simulated period of starting, running and stopping.
•Selecting the Case Summary menu item.
•Clicking the Tension tab icon.
•The plot point set defines the points which can be selected for plotting. These can be edited. They are the same points displayed in the individual case simulation output display and charts.
•Select the point from the "Selected Plot Point:" drop-down list.
A table of the minimum and maximum values for each case is displayed below the chart with the descriptions color coded to the lines. Clicking on the box next to a specific case description determines whether the line is displayed on the graph.
•If it is colored, the line is shown; if it is empty (white) then it is not shown.
•If are many cases and want to display just one of them, right-click on the color box of the desired case to show only that line. Attempting to hide the only showing line results in all lines being shown again.
The plot begins with the starting sequence and then goes to the stopping sequence. The chart shading indicates the transition point. This range can be reduced by dragging the scroll bar between the chart and time axis labels.
If the stating simulation time is long enough, the plot at the end of the starting data should be constant and represent the running condition.
The thin gray line indicates the rating of the belt; the thin red line indicates the belt tension acceptable during starting and stopping (both imported from BA).
By right clicking on the chart, the user can either create a "csv" text file of the chart data,a "png" picture file of the image or copy to clipboard.
See Also: Plot Points, Case Summary Output