<< Click to Display Table of Contents >> Power Wizard |
Available in v14 and higher
Available in Suite
Updated in v18.2
To access Power Wizard, the user must be using CEMA 7 (to switch to a different to calculation methods please see Calculation Methods). The user must click on the Analysis > Power Wizard menu item.
Power Wizard can plot either Demand Power or f Factor results over a temperature range.
Users can test the effects of changing Idler Drag, Angular Install Tolerance and the Belt Cover Multiplier on the power. Each line item in the grid is a different test case and all three variables can be modified by a percentage up or down to observe the effects. Additional line items can be added or removed using the "+" or "-" buttons on the side of the grid.
To run the calculation click the Calculate button; this will run through each line item in the grid and when finished display the results in the main view area.
After calculating results, the user can choose to apply the conditions of any line item to the currently selected case in Belt Analyst by clicking the apply button. This will overwrite the Idler Drag, Angular Install Tolerance and the Belt Cover Multiplier variables in the current case.
Individual plot lines can be toggled on or off by left clicking the legend color box. Alternatively if the user right clicks a box it will show only the plot selected and hide all others
A reference line can be added by checking the Min Allowable check box.
When plotting estimated power requirement, the reference line is typically the installed power.
The image of the chart can be saved by right clicking on the chart.
•Export To Image: will save "png" image of chart to selected directory location.
•Export To CSV: save data points to "csv" text file.
•Copy To Clipboard: allows image to be pasted to a document location.